Configuration (Minimum & Maximum Capacity)
|
18 kVA to 90 kVA
|
108 kVA to 550 kVA
|
600 kVA to 2000 kVA
|
30 kVA to 600 kVA
Transformer with APFC
|
(Solutions in Lighting)
18 kVA to 500 kVA
|
TECHNICAL SPECIFICATIONS FOR
HARDWARE SYSTEM
|
ATW Zigzag Transformer
|
Available
|
Available
|
Available
|
Available
|
-
|
Phase Voltage-3Phase-4Wire & 415V,+/-5%
|
Available
|
Available
|
Available
|
Available
|
Available
|
Duty Cycle Continues (24x7 )
|
Available
|
Available
|
Available
|
Available
|
Available
|
Cooling - Natural Air
|
Available
|
Available
|
Available
|
Available
|
Available
|
Average Savings 10% Achieves
|
Available
|
Available
|
Available
|
Available
|
20% & Above
|
Protects Transients & Impulses
|
Available
|
Available
|
Available
|
Available
|
Available
|
Power Conditioning Benefits
|
Available
|
Available
|
Available
|
Available
|
Available
|
It ensures that only the required quantity of Power is supplied
|
Available
|
Available
|
Available
|
Available
|
Available
|
Reduces Harmonic Distortion (THD)
|
Available
|
Available
|
Available
|
Available
|
Available
|
Improves Phase Balancing
|
Available
|
Available
|
Available
|
Available
|
-
|
Incrementally Improves Power Factor (P.F.)
|
Available
|
Available
|
Available
|
.999 to Unity
|
-
|
Improves the life & efficiency of the Electronics & Electrical Equipment
|
Available
|
Available
|
Available
|
Available
|
Improves Life of Lamps & Chokes
|
Life of Energy Equipment more than 20 to 25 Years except Capacitors
|
Available
|
Available
|
Available
|
Available
|
Available
|
Transformer Efficiency >99%
|
Available
|
Available
|
Available
|
Available
|
Available
|
Energy Saving Transformer With Capacitor Bank up to 300 kVAR
|
-
|
-
|
-
|
Available
|
-
|
Over & Under Voltage Auto Bypass
|
Available
|
Available
|
Available
|
Available
|
-
|
Short Circuit & Transformer’s Protection of Input side & Output side with Miniature Circuits i.e. MCB / MCCB / ACB
|
Available
|
Available
|
Available
|
Available
|
Available
|
Suitable for sites with highly Fluctuation in the Voltage Profile
|
Available
|
Available
|
Available
|
Available
|
Available
|
Transformer Temperature Controller with Indicator Circuit
|
-
|
Optional
|
Available
|
-
|
-
|
Easy to Bypass for Maintenance without affecting the Power supply Network
|
Available
|
Available
|
Available
|
Available
|
Available
|
Micro Processor based LSIG Protection
|
-
|
Optional
|
Optional
|
-
|
-
|
Insulation class ‘F’ & ‘H’.
|
Available
|
Available
|
Available
|
Available
|
Available
|
Insulation 3 KV line to Earth
|
Available
|
Available
|
Available
|
Available
|
Available
|
LED Indicators & LCD Status Energy Meter
|
Available
|
Available
|
Available
|
Available
|
Available
|
Enclosures IP 32, (IP 34, 42,54,55 & 56 optional)
|
Available
|
Available
|
Available
|
Available
|
Available
|
Eltrak Energy Monitoring Software System (Power Analyser )
|
Optional
|
Optional
|
Available
|
Optional
|
Optional
|
Cable Terminals
Bottom Entry/Top Entry Heavy duty Input & Output cable chamber & Bus Bars Terminals.
|
Available
|
Available
|
Available
|
Available
|
Available
|
Installation Indoor Facility (Outdoor Facility Optional)
|
Available
|
Available
|
Available
|
Available
|
Available
|
Selectable programming & setting to suit conditions for % Savings & off Circuit Tap Changer.
|
Available
|
Available
|
Available
|
Available
|
Available
|
TECHNICAL SPECIFICATIONS FOR
ELTRAK SOFTWARE SYSTEM
|
Continuous (24x7) tracking of your electricity usage. No one can waste & misuse your power
|
Optional
|
Optional
|
Available
|
Optional
|
Optional
|
Publish live data with graphics, trends, reports & Alarms etc., with bi-directional connectivity
|
Optional
|
Optional
|
Available
|
Optional
|
Optional
|
On line alarm if values are about to exceed Set Maximum & Minimum limit i.e. P.F, I & V M.D. & THD etc.
|
Optional
|
Optional
|
Available
|
Optional
|
Optional
|
Auto backup & data reference features.
|
Optional
|
Optional
|
Available
|
Optional
|
Optional
|
Access your Electrical Parameters & Reports from anywhere in the World
|
Optional
|
Optional
|
Available
|
Optional
|
Optional
|
System Capacity
Dimensions & Weight (In Feet & In Kilogram mentioned minimum to Maximum kVA Capacity Range Approximate)may change as per site requirement
|
For 18kVA to 90kVA Capacity
2x1x2 to 2.6x1.6x2.6 & 32kg to 175kg.
|
For 108kVA to 550kVA Capacity 3.5x1.6x3.5 to 5x2.6x5 & 180kg to 785kg
|
600kVA to 2000kVA Capacity 6x3x6 to 10x6x10 & 845Kg. to 2850kg
|
18kVA to 600kVA Capacity 2.6x1.6x2.6 to 6.5x3.5x6.5 & 78kg. to 1250kg
|
18kVA to 600kVA Capacity
2x1x2 to 6x3x6 & 32 kg to 845kg. Ranges in Between
|